sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter or negative. That is, the result of the forward 20.00Hz and reverse 40.00Hz is reverse 40.00Hz. During the main and auxiliary operations, the range of the auxiliary frequency source B depends on the selected object, maximum frequency by default. If selected relative to the main frequency source A (F00.09=1), the range of the auxiliary frequency source B will change along with that of the main frequency source A (according to the maximum frequency by default).

Such parameters are mainly used to adjust the gain of each setting source, as shown in 139 Function Default Function code name Parameter description Unit Attribute code setting F00.09 Reference options of auxiliary frequency source B in main and auxiliary operation 0: relative to he maximum frequency 1: Relative to main frequency source A 0 〇 Function Default Function code name Parameter description Unit Attribute code setting F00.10 Gain of main frequency source 0.0~300.0 % 100.0 ● F00.11 Gain of auxiliary frequency source 0.0~300.0 % 100.0 ● F00.12 Synthetic gain of main and auxiliary frequency sources 0.0~300.0 % 100.0 ● F00.13 Analog adjustment of synthetic frequency 0:

synthetic frequency of main and auxiliary channels 1: AI1 * synthetic frequency of main and auxiliary channels 2: AI2 * synthetic frequency of main and auxiliary channels 3: retention 4: retention 5: High frequency pulse (PULSE) * synthetic frequency of main and auxiliary channels 0 〇