User Manual of EM730/EM730E Series Inverter Normal running status: Upon receiving a valid start command (from the keyboard, control terminal and communication), the inverter will have the output based on the set input requirements, driving the motor to rotate. Jog running status: This is enabled by the keyboard, external terminal or communication, driving the motor to rotate at the jog input speed. Self-learning running status: This is enabled by the keyboard, detecting relevant parameters of the motor in the stationary or rotating status. Stop status:
It is a process for the output frequency to decrease to zero according to the set deceleration time in the case of invalid operating commands. Jog stop status: It is a process for the output frequency to decrease to zero according to Protection status: Refer to the inverter status in the case of any protection. the jog deceleration time in the case of invalid jog operating commands. 1.2.2 Running mode of inverter The running mode of the inverter refers to the control law of the inverter to drive the motor to rotate at the required speed and torque. The running mode includes: General open-loop space vector control-VVF control:
suitable for applications where the speed is not changing fast and there are not high requirements for the accuracy of rotating speed, and most AC motor drives. Speed sensorless vector control-SVC control: advanced speed estimation algorithm, 1.2.3 Set mode of inverter involving open-loop vector control and high control accuracy but no encoder. The set mode of the inverter refers to the physical quantity that is taken as the controlled target when the inverter drives a motor.
Speed setting mode with the motor speed as controlled target digital potentiometer setting, process PID setting, simple PLC setting or multi-segment speed Digital setting, analog input setting, high-speed pulse input setting, communication setting, setting can be performed separately or in a mixed manner. Fig. 1-1to Fig. 1-4 detail various input modes of the EM730/EM730E series inverter by speed setting. 14