User Manual of EM730/EM730E Series Inverter F05.07=2:AI2 F05.07=4: High-frequency pulse (X5) of VF separation voltage). The VF separation output voltage depends on AI/HDI (percentage) * F05.08 (digital setting For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same meaning. 100.00% is the percentage to the set value of F05.08 (digital setting of VF separation voltage). F05.07=5: process PID The VF separation output voltage depends on the process PID function output, as described in 7.10. F05.07=6: communication setting The VF separation output voltage depends on the communication.

 If the master-slave communication (F10.05=1) is enabled and the inverter works as the slave (F10.06=0), the VF separation output voltage is “700FH (master-slave communication setting) * F01.02 or others (rated voltage of the motor) * F10.08 (slave receiving proportional coefficient)”. The 700FH data range is 0.00% to 100.00%, as detailed in Table 12-31.  For general communication (F10.05=0), the VF separation output voltage is “7006H (voltage setting of the VF separation mode) * F05.08 (digital setting of the VF separation voltage)”, and the 7006H data range is 0.00% to 100.00%, as detailed in Table 12-31.

The rise time of VF separation voltage refers to the time for the output voltage to increase from 0 to the rated voltage of the motor. 189 Function Default Function code name Parameter description Unit Attribute code setting F05.09 Rise time of VF separation voltage 0.00 - 60.00 s 2.00 ●