User’s Guide for EM760 series high-performance vector inverter above 50℃, derating by 1.5% per 1℃ temperature rise to maximum 60℃). Contact us for technical advice. Precautions for scrapping of inverter Burning of the electrolytic capacitors of the main circuit and printed circuit board may result in explosion, and burning of plastic parts may generate toxic gases. Please dispose of the controller as a kind of industrial waste. Scope of application This product is not designed and manufactured as a device or system of vital importance. Do not use this product in these cases. This product is manufactured under strict quality management.
When failure of this product may cause a major accident or loss, please install a safety device. Prevention of electric shock Please read all requirements of safety precautions! Maintenance of the inverter must be carried out 10 min after the main circuit is powered off and the display interface of the keyboard is disabled; otherwise, the residual charge in the capacitor will do harm to the human body! Anti-toppling The cabinet has an anti-toppling label attached onto it. You may check the label upon receiving the goods to know transport condition of the goods and reject the goods if the label color has changed.
Transportation When you select transport of the inverter in a cabinet, it is necessary to protect the whole cabinet with anti-shock measures. 6