omron — Specifications

Specifications 1 2 : : Under development. The maximum applicable motor output is given for a standard 4- pole Yaskawa motor. When selecting the actual motor and MxC, be sure that the MxC’s rated current is applicable for the motor's rated current. The rated current will vary in accordance with the values of the voltage or impedance of the power supply (including the power transformer, the input reactor, and wires). Required to reduce the rated output current in accordance with the values of the carrier frequencies or control mode. Rotational autotuning must be performed to ensure obtaining the specifications given for open - loop or flux vector control.

The speed control accuracy depends on the installation conditions and type of motor used. Contact your Yaskawa representative for details. Applications with repetitive loads may require derating (reducing carrier frequency and current, which involves increasing the frame size of the MxC). Contact your Yaskawa representative for details. If the CIMR - ACA 25 P 5 , 2011 , 2022 , 45 P 5 , or 4011 needs two seconds or more for the momentary power loss ridethru time, a back-up capacitor unit for momentary power loss is necessary. If L 2-01 (Momentary Power Loss Detection Selection) is enabled, the MxC will stop 2 ms after the momentary power loss occurs.

Contact your Yaskawa representative for details about use in applications, such as trolley cranes, with a tendency to have momentary power losses or open phases. The ground fault here is one which occurs in the motor wiring while the motor is running. A ground fault may not be detected in the following cases. A ground fault with low resistance which occurs in motor cables or terminals. A ground fault occurs when the power is turned on. 3 4 5 6 7 : : : : : 8 : 10 9 : Voltage Class 200 V 400 V Model Number CIMR-ACA 25P5 2011 2022 2045 1 45P5 4011 4022 4045 1 4075 1 Max.

Applicable Motor Output 2 kW 5.5 11 22 45 5.5 11 22 45 75 Rated Input Current 3 A 26 47 91 − 14 26 49 − − Output Characteristics Rated Output Capacity kVA 9 17 33 − 10 19 36 − − Rated Output Current 4 A 27 49 96 − 15 27 52 − − Max. Output Voltage 95 % of input voltage Max. Output Frequency Frequencies supported up to 120 Hz using parameter setting Power Supply Characteristics Rated Voltage and Frequency 3-phase, 200/208/220 V, 50/60 Hz 3-phase, 380/400/415/440/460/480 V, 50/60 Hz Allowable Voltage Fluctuation +10% to −15% Allowable Frequency Fluctuation ±3% (Frequency fluctuation rate:

1 Hz/100 ms or less) Allowable Power Voltage Imbalance between Phases Within 2% Input Power Factor 0.95 or more (When the rated load is applied.) Control Characteristics Control Method Sine-wave PWM [Flux vector control, open-loop vector control, V/f control (switched by parameter setting)] Torque Characteristics 150% / 0 Hz (Flux vector control) 5 Speed Control Range 1 : 1000 (Flux vector control) 5 Speed Control Accuracy 6 ±0.2% (Open-loop vector control : 25˚C ±10˚C) 5, ± 0.05% (Flux vector control :

25˚C ±10˚C) 5 Speed Control Response 30 Hz (Flux vector control) 5 Torque Limits Provided for vector control only (4 quadrant steps can be changed by parameter settings.) Torque Accuracy ±10% (Flux vector control : 25˚C ±10˚C with a vector motor, carrier frequency of 4 kHz) 5 Frequency Control Range 0.01 Hz to 120 Hz Frequency Accuracy (Temperature Characteristics) Digital reference : ± 0.01% (−10˚C to +40˚C), Analog reference : ±0.1% (25˚C ±10˚C) Frequency Setting Resolution Digital reference : 0.01 Hz, Analog reference :

0.03 Hz / 60 Hz (11bit with no sign) Output Frequency Resolution 0.001 Hz Overload Capacity 7 150% of rated output current per minute (for carrier frequency of 4 kHz) Accel/Decel Time 0.00 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) Braking Torque Same overload capacity for motoring and regeneration Main Control Functions Momentary power loss restart, Speed search, Overtorque detection, Torque limit, 17-speed control (maximum), Accel/decel time change, S-curve accel/decel, 3-wire sequence, Autotuning (rotational or stationary), Dwell function, Cooling fan ON/OFF control, Slip compensation, Torque compensation, Jump frequency, Frequency upper/lower limit settings, DC injection braking at start/stop, PID control (with sleep function), MEMOBUS communication (RS-485/422, max.19.2 kbps), Fault restart, Droop control, Parameter copy, Torque control, Speed/torque control switching, etc.

Protective Functions Regenerative Function Provided Motor Protection Protection by electronic thermal overload relay. Instantaneous Overcurrent Stops at approx. 200% of rated output current. Fuse Blown Protection Stops for fuse blown. Overload Protection 150% of rated output current per minute (for carrier frequency of 4 kHz) Overvoltage Protection Stops when input power supply voltage is greater than 250 VAC. Stops when input power supply voltage is greater than 550 VAC. Undervoltage Protection Stops when input power supply voltage is less than 150 VAC. Stops when input power supply voltage is less than 300 VAC. Momentary Power Loss Stops for 2 ms or more.

By parameter setting, operation can be continued if power is restored within 2 s. 8 Cooling Fin Overheating Protection by thermistor. Stall Prevention Stall prevention during acceleration, deceleration, or running. Grounding Protection 9 Protection by electronic circuits. (Overcurrent level) Charge Indicator Lit when the main circuit DC voltage is approx. 50 V or more. Environment Ambient Operating Temperature −10˚C to +40˚C (Enclosed wall-mounted type), −10˚C to +45˚C (Open chassis type) Ambient Operating Humidity 95% max.

(with no condensation) Storage Temperature −20˚C to +60˚C (short-term temperature during transportation) Application Site Indoor (no corrosive gas, dust, etc.) Altitude 1000 m max. Vibration 10 to 20 Hz : 9.8 m/s2, 20 to 55 Hz : 5.9 m/s2 Protective Structure Open chassis type (IP00) and enclosed wall-mounted type (NEMA1)