Command List of the Alphabetical Order 1 "Priority" indicates the function is executed with priority. ESC/Label Command List Rev. C SHEET8 CW-C4000 series Command Function identifier Command name Description Classification Command code Description of parameters Definition range for ESC/Label Definition range Factory-set initial value Corresponding ZPL II command Priority 1 ^BX Data Matrix Sets the Data Matrix symbol to the field. Barcode ^BXo,s,e,c,r,d,i,f o: Data Matrix field orientation o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) ^BX Low s:
Data Matrix module size [dot] 1 ≤ s ≤ 32000 1 ≤ s ≤ 9600 e: Data Matrix error correction level e = 0/50/80/100/140/200 0: ECC000 50: ECC050 80: ECC080 100: ECC100 140: ECC140 200: ECC200 e = 200 200: ECC200 c: Data Matrix column count 9 ≤ c ≤ 49 If e = 200, then 10 ≤ c ≤ 144 square (f = 1): c = 10/12/14/16/18/20 /22/24/26/32/36/40 /44/48/52/64/72/80/88 /96/104/120/132/144 rectangular (f = 2): r = 8: c = 18/32 r = 12: c = 26/36 r = 16: c = 36/48 r: Data Matrix line count 9 ≤ r ≤ 49 If e = 200, then 8 ≤ r ≤ 144 square (f = 1): r = 10/12/14/16/18/20 /22/24/26/32/36/40/ 44/48/52/64/72/80/88 /96/104/120/132/144 rectangular (f = 2): r = 8/12/16 d: Data Matrix data type d = 1/2/3/4/5/6 1:
Numerals and blank characters 2: Capital letters of the alphabet (A to Z) and blank characters 3: Numerals, capital letters of the alphabet (A to Z), blank characters, periods , commas , dashes , and slashes . 4: Numerals, capital letters of the alphabet (A to Z), and blank characters 5: ASCII code (00H to 7EH) 6: ASCII code (00H to FFH) d = 1/2/3/4/5/6 1: Numerals and blank characters 2: Capital letters of the alphabet (A to Z) and blank characters 3: Numerals, capital letters of the alphabet (A to Z), blank characters, periods , commas , dashes , and slashes . 4: Numerals, capital letters of the alphabet (A to Z), and blank characters 5: ASCII code (00H to 7EH) 6:
ASCII code (00H to FFH) i: Data Matrix ECC200 escape sequence identifier Any ASCII single character Any ASCII single character f:Data Matrix ECC200 symbol shape f = 1/2 1: Square 2: Rectangle f = 1/2 1: Square 2: Rectangle ^BY Set barcode parameters default values Sets the default values for parameters used in barcodes. Barcode ^BYx,n,h x: Module width [dot] 1 ≤ x ≤ 9999 1 ≤ x ≤ 85 ^BY Low n: Bar width ratio 2.0 ≤ n ≤ 3.0 2.0 ≤ n ≤ 3.0 h: Barcode height [dot] 1 ≤ h ≤ 32000 1 ≤ h ≤ 9600