EPSON — ^BR

[Function]  Sets the GS1 DataBar, the UPC, or the EAN barcode, or Composite symbol to the field.  Sets the field orientation based on Parameter o.  Sets the symbol type based on Parameter t.  Sets the module size for symbol rendering based on Parameter m.  Sets the height of separator based on Parameter s. Parameter s is enabled only when 1, 2, 3, 4, 5, 6, 11, or 12 is specified for Parameter t.  Sets the height of barcode part of UCC/EAN-128 and CC-A/CC-B/CC-C based on Parameter h. Parameter h is enabled only when 11 or 12 is specified for Parameter t.  The number of segments per line for GS1 DataBarExpanded is set based on Parameter n.

Parameter n is enabled only when 6 is specified for Parameter t. [Encoding]  Composite symbols can be specified by including a vertical bar in the field data. In this case, Parameter t is set to the symbol type in the following table.  If encoding a Composite symbol, a vertical bar in the field data is treated as a separator. Data before the vertical bar is encoded as barcode data, and data after the vertical bar is encoded as 2- dimensional code data. [Response] None [Reference] Related commands: ^FW ESC/Label Command Reference Guide Rev.

L Page 79 Value of Parameter t Symbol type 1 GS1 Standard and CC-A/CC-B 2 GS1 DataBar Truncated and CC-A/CC-B 3 GS1 DataBar Stacked and CC-A/CC-B 4 GS1 DataBar Stacked Omnidirectional and CC-A/CC-B 5 GS1 DataBar Limited and CC-A/CC-B 6 GS1 DataBar Expanded and CC-A/CC-B 7 UPC-A and CC-A/CC-B 8 UPC-E and CC-A/CC-B 9 EAN-13 and CC-A/CC-B 10 EAN-8 and CC-A/CC-B 11 UCC/EAN-128 and CC-A/CC-B 12 UCC/EAN-128 and CC-C