omron — FSET program instruction

FSET program instruction FSET Serial-Line Attributes Using FSET With TCP The following network devices may be referenced with the FSET> instruction: TCP Transmission Control Protocol You can use the attributes listed in the following table when accessing these devices with the FSET instruction: FSET Attributes for Networks You may define new nodes on the network using the FSET program instruction to access a logical unit that has been attached to the TCP device.

The string used with the FSET eV+Language Reference Guide, v2.x, 18319-000 Rev A Page 264 Attribute Argument Description /PARITY NONE No parity generation EVEN Use even parity ODD Use odd parity /STOP BITS _ 1 or 2 Use 1 or 2 stop bits per byte /BYTE LENGTH _ 7 or 8 Use 7 or 8 bits per byte /FLOW NONE No flow control XON XOFF _ Detect and generate XON/XOFF (turn off modem) MODEM Use modem control RTS/CTS (turn off XON XOFF). _ /SPEED 110, 300, 600, 1200, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200 Select the indicated baud rate. Attribute Description /ADDRESS IP address. (Applies only to the TCP device.) /NODE Node name.