PARAMETER monitor command PARAMETER monitor command Syntax PARAMETER parameter [index] = value Function Set or display the values of system parameters. Usage Considerations If the equal sign and value are omitted, the parameter is not changed, and its current value is displayed on the system terminal. If no parameter is specified, the current values of all parameters are displayed on the terminal. Parameters parameter Name of the parameter whose value is to be displayed or modified. The name must be specified when the equal sign and a value are included in the command to modify the parameter value. The name can be omitted when the command is being used to display parameter values.
When specified, the parameter name can be abbreviated. index For parameters that can be qualified by an index, this is an optional real value, variable, or expression that specifies the specific parameter element of interest. value Optional real value, variable, or expression defining the value to be assigned to the system parameter. The equal sign must be omitted if no value is specified. Details If a value is specified, the specified system parameter is set to the value on the right-hand side of the equal sign. The parameter name can be abbreviated to the minimum length that identifies it uniquely. NOTE:
The regular assignment statement cannot be used to set the value of a system parameter. The following table lists the basic system parameters. Other system parameters are available when options are installed. Refer to the option documentation for details. eV+Operating System Reference Guide, 2.x,18321-000 Rev A Page 139