omron — 6.7. Moving Robot to Robot Approach Position at Measurement.

The Vision Sensor measurements are received using "fhrunrecvval". In this sample program, it is assumed that the Vision Sensor measurements are sent in the order "TJG X Y Z W P R". For a processing to move the robot to the robot approach position at measurement, follow the procedures below. 34 6.6. Getting the Measurement Results 1 In order to receive the measurement results from the Vision Sensor, we execute "fhrunrecvval" and check the received overall judgment value.

;Get the Measurement Result CALL fhrunrecvval(retry_count, time_out, socket_no, param[], err_no) numerical sequence receiving function ;Error check IF err_no success THEN GOTO 10 END ;Total Judge Check IF param[0] 1 THEN If the overall judgment is not OK, exit the program GOTO 10 Set the measurement results to the variables. ; Measurement results res cmd pos x = param[1] _ _ _ res cmd pos y = param[2] _ _ _ res cmd pos z = param[3] _ _ _ res cmd pos w = param[4] _ _ _ res cmd pos p= param[5] _ _ _ res cmd pos r = param[6] _ _ _ TYPE "Measurement Done" 2 6.7. Moving Robot to Robot Approach Position at Measurement.

1 By the procedures at the step 2 in Chapter 6.6, check that the measurement results are stored in the variables