Mitsubishi — 5.1.1 Parameter list (by parameter number)

74 5. PARAMETERS 5.1 Parameter list Pr. Pr.

group Name Setting range Minimum setting increment Initial value Refer to page Customer setting — 65 H300 Retry selection 0 to 5 1 0 115 — 66 H611 Stall prevention operation reduction starting frequency 0 to 400 Hz 0.01 Hz 50 Hz 119 Retry 67 H301 Number of retries at fault occurrence 0 to 10, 101 to 110 1 0 115 68 H302 Retry waiting time 0.1 to 600 s 0.1 s 1 s 115 69 H303 Retry count display erase 0 1 0 115 — 71 C100 Applied motor 0 to 2 1 0 147, 147 — 72 E600 PWM frequency selection 2 to 12 1 2 92 — 73 T000 Analog input selection 0, 1, 10, 11 1 1 131 — 74 T002 Input filter time constant 0 to 8 1 1 134 — 75 — Reset selection/ disconnected PU detection/ PU stop selection 0 to 3, 14 to 17 1 14 85 E100 Reset selection 0, 1 0 E101 Disconnected PU detection E102 PU stop selection 1 — 77 E400 Parameter write selection 0 to 2 1 2 89 — 78 D020 Reverse rotation prevention selection 0 to 2 1 0 108 — 79 D000 Operation mode selection 0 to 4 1 0 100, 104 Motor constant 80 C101 Motor capacity 0.2 to 15 kW, 9999 0.01 kW 9999 147 82 C125 Motor excitation current 0 to 500 A, 9999 0.01 A 9999 147 90 C120 Motor constant (R1) 0 to 50 Ω, 9999 0.001 Ω 9999 147 96 C110 Auto tuning setting/status 0, 1 1 0 147 Adjustable 3 points V/F 100 G040 V/F1 (first frequency) 0 to 400 Hz, 9999 0.01 Hz 9999 195 101 G041 V/F1 (first frequency voltage) 0 to 1000 V 0.1 V 0 V 195 102 G042 V/F2 (second frequency) 0 to 400 Hz, 9999 0.01 Hz 9999 195 103 G043 V/F2 (second frequency voltage) 0 to 1000 V 0.1 V 0 V 195 104 G044 V/F3 (third frequency) 0 to 400 Hz, 9999 0.01 Hz 9999 195 105 G045 V/F3 (third frequency voltage) 0 to 1000 V 0.1 V 0 V 195 PU connector communication 117 N020 PU communication station number 0 to 31(0 to 247) 1 0 168 118 N021 PU communication speed 48, 96, 192, 384, 576, 768, 1152 1 192 168 119 — PU communication stop bit length / data length 0, 1, 10, 11 1 1 168 N022 PU communication data length 0, 1 0 N023 PU communication stop bit length 0, 1 1 120 N024 PU communication parity check 0 to 2 1 2 168 121 N025 PU communication retry count 0 to 10, 9999 1 1 168 122 N026 PU communication check time interval 0, 0.1 to 999.8 s, 9999 0.1 s 0 168 123 N027 PU communication waiting time setting 0 to 150 ms, 9999 1 ms 9999 168 124 N028 PU communication CR/LF selection 0 to 2 1 1 168 — 125 T022 Terminal 2 frequency setting gain frequency 0 to 400 Hz 0.01 Hz 50 Hz 134 — 126 T042 Terminal 4 frequency setting gain frequency 0 to 400 Hz 0.01 Hz 50 Hz 134