4 G: Control parameters 2 Parameters for motor control. 3 4 5 6 7 8 N: Communication operation parameters 9 Parameters for the setting of communication operation such as the communication specifications or operating characteristics. 10 *1 The parameter number in parentheses is the one used (displayed) on the LCD operation panel and the parameter unit. 83 5. PARAMETERS 5.1 Parameter list Pr. group Pr.
Name Refer to page A302 594 Amplitude compensation amount during deceleration 151 A303 595 Amplitude compensation amount during acceleration 151 A304 596 Amplitude acceleration time 151 A305 597 Amplitude deceleration time 151 A601 131 PID upper limit 152 A602 132 PID lower limit 152 A610 128 PID action selection 152 A611 133 PID action set point 152 A612 127 PID control automatic switchover frequency 152 A613 129 PID proportional band 152 A614 130 PID integral time 152 A615 134 PID differential time 152 A621 575 Output interruption detection time 152 A622 576 Output interruption detection level 152 A623 577 Output interruption cancel level 152 A680 573 4 mA input check selection 139 A702 57 Restart coasting time 159 A703 58 Restart cushion time 159 A710 165 Stall prevention operation level for restart 159 A730 261 Power failure stop selection 160 Pr.
group Pr. Name Refer to page N028 124 PU communication CR/LF selection 168 N080 343 Communication error count 182 Pr. group Pr.
Name Refer to page G000 0 Torque boost 193 G001 3 Base frequency 194 G002 19 Base frequency voltage 194 G030 60 Energy saving control selection 195 G040 100 V/F1 (first frequency) 195 G041 101 V/F1 (first frequency voltage) 195 G042 102 V/F2 (second frequency) 195 G043 103 V/F2 (second frequency voltage) 195 G044 104 V/F3 (third frequency) 195 G045 105 V/F3 (third frequency voltage) 195 G100 10 DC injection brake operation frequency 197 G101 11 DC injection brake operation time 197 G106 250 Stop selection 198 G110 12 DC injection brake operation voltage 197 G120 882 Regeneration avoidance operation selection 199 G121 883 Regeneration avoidance operation level 199 G123 885 Regeneration avoidance compensation frequency limit value 199 G124 886 Regeneration avoidance voltage gain 199 G125 665 Regeneration avoidance frequency gain 199 G130 660 Increased magnetic excitation deceleration operation selection 200 G131 661 Excitation increase rate 200 G132 662 Increased magnetic excitation current level 200 G203 245 Rated slip 202 G204 246 Slip compensation time constant 202 G205 247 Constant-power range slip compensation selection 202 Pr.
group Pr. Name Refer to page N000 549 Protocol selection 165 N001 342 Communication EEPROM write selection 165 N013 502 Stop mode selection at communication error 165 N020 117 PU communication station number 168 N021 118 PU communication speed 168 N022 119 PU communication data length 168 N023 119 PU communication stop bit length 168 N024 120 PU communication parity check 168 N025 121 PU communication retry count 168 N026 122 PU communication check time interval 168 N027 123 PU communication waiting time setting 168