Mitsubishi — Safety instructions

 Additional instructions The following instructions must be also followed. If the product is handled incorrectly, it may cause unexpected fault, an injury, or an electric shock. CAUTION Transportation and installing  Any person who is opening a package using a sharp object, such as a knife or cutter, must wear gloves to prevent injuries caused by the edge of the sharp object.  The product must be transported in correct method that corresponds to the weight. Failure to do so may lead to injuries.  Do not stack the boxes containing products higher than the number recommended.  Do not stand or place any heavy object on the product.

 When carrying the product, do not hold it by the front cover. Doing so may cause a fall or failure of the product.  During installation, caution must be taken not to drop the inverter as doing so may cause injuries.  Do not install the product on a hot surface.  The product must be installed on the surface that withstands the weight of the product.  The installing orientation of the inverter must be correct.  The inverter must be installed on a strong surface securely with screws so that it does not drop.  Do not install or operate the inverter if it is damaged or has parts missing.  Foreign conductive objects must be prevented from entering the inverter.

That includes screws and metal fragments or  As the inverter is a precision instrument, do not drop or subject it to impact. other flammable substance such as oil.  The surrounding air temperature must be between -10 and +40°C *1 (non-freezing). Otherwise the inverter may be damaged.  The ambient humidity must be 95% RH or less (non-condensing) for the inverter. Otherwise the inverter may be damaged. (Refer to page 23 for details.)  The temporary storage temperature (applicable to a short limited time such as a transportation time) must be between -  The inverter must be used indoors (without corrosive gas, flammable gas, oil mist, dust and dirt). Otherwise the inverter 20 and +65°C.

Otherwise the inverter may be damaged. may be damaged.  The inverter must be used at an altitude of 2500 m or less, with 5.9 m/s 2 or less vibration at 10 to 55 Hz (directions of X, Y, Z axes). Otherwise the inverter may be damaged. (For the installation at an altitude above 1000 m, consider a 3% reduction in the rated current per 500 m increase in altitude. Refer to page 23 for details.)  If halogen-based materials (fluorine, chlorine, bromine, iodine, etc.), included in fumigants to sterilize or disinfect wooden packages, infiltrate into the product, the product may be damaged.

Prevent residual fumigant components from being infiltrated into the product when packaging, or use an alternative sterilization or disinfection method (heat disinfection, etc.). Note that sterilization of disinfection of wooden package should be performed before packing the product. Wiring  Do not install a power factor correction capacitor, surge absorber, or radio noise filter on the inverter's output side. These devices on the inverter output side may be overheated or burn out.  The output of the inverter (output terminals U, V, W) must be correctly connected to a motor. Otherwise the motor rotates inversely.

Test operation  Before starting the test operation, confirm or adjust the parameter settings. A failure to do so may cause some machines to make unexpected motions. *1 40 to 50°C (non-freezing) at the rated current reduced by 15%. 8