4-26 POWER TAKE-OFFS E UROCARGO Euro 4/5 Isochronous control of engine rate For power take-offs when you want to set different values for N res and N SET_max and N SET_min than the ones set (e.g., to avoid overrevving at the pumps), the system enables saving the new values in the control unit. This operation is performed by the Centres of the IVECO Network equipped with EASY stations, providing the following indications: • Type of vehicle; no. of chassis frame • Type of engine; serial number • desired N res (rpm) • desired N SET_max (rpm) • desired N SET_min (rpm) The system allows adjustment of N res up to N SET_max - 50 (rpm). Using the MODUS/E.A.SY.

station must be preceded b updating the EASY software. NOTE Isochronous control of engine rate Base - January 2008 Print 603.93.431