5-6 SPECIAL INSTRUCTIONS FOR ELECTRONIC SUBSYSTEMS E UROCARGO Euro 4/5 Table 5.1 - (follows from preceding page) Figure 5.3 ST 13 without Cruise Control ST 13 with Cruise Control CC OFF Steering column switch Switch BB Switch BB Cut and isolate the jumper Vehicle wiring Switch BB Vehicle wiring Switch BB A jumper joins pins 14 and 16 (dotted connection 5.3). If the Cruise Control is used via external connector ST13, the jumper must be cut and isolated. 116639 !
Use of the motor start/stop signal requires prior installation of the necessary devices to guarantee that the operation takes place in complete safety and in compliance with current regulations, both for the safety of the operator and for the persons and/or property around the vehicle. It will be to the bodybuil- der’s care and responsibility to identify and make these devices correctly (e.g. parking brake engaged, gearbox in neutral, etc), using solutions that ensure the required function and components of proven reliability. Bodybuilder connectors Base - January 2008 Print 603.93.431 Connections Pin Description Type Cable code Max.
load Observations 17 Ground POWER 0000 10A Ground 18 PTO mode 1 INPUT 0131 10 mA PTO mode1 Circuit open = PTO mode 1 not activated Closed toward ground = PTO mode 1 activated 19 PTO mode 2 INPUT 0132 10 mA PTO mode2 Circuit open = PTO mode 2 not activated Closed toward ground = PTO mode 2 activated 20 PTO mode 3 INPUT 0123 10 mA PTO mode3 Circuit open = PTO mode 3 not activated Closed toward ground = PTO mode 3 activated 21 K30 POWER 7772 10 A K30