Installation CAUTION: It is critical that the OMAS Cable is correctly positioned in the Vacuum Beam so that it does not cause physical interference to the Media Sensor. The following illustration shows a cross-section of the Vacuum Beam with the OMAS Cable correctly routed to avoid interference to the Media Sensor. Platen OMAS OMAS Cable Removal & Installation Media Sensor 1. Before you can start to install the OMAS Cable you must first identify which end connects to which component. The end of the cable that has the most perpendicular and diagonal folds is the end that connects to the OMAS with the blue reinforcing on the top.
The other end must be connected to the OMAS Controller Card with the blue reinforcing on the bottom. OMAS OMAS Controller Card 1. Carefully slide the Ferrite Core and its associated attachment plate out of the vacuum beam. 366 Chapter 8 Removal & Installation