• If the System Error continues, replace the Hard Disk Drive ⇒ Page 377. System Error: 06:10 Problem Description: Main NVM failure - not detected, read/write failed or readback error. Corrective Action: System Error Codes Try the following: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • If the System Error continues, replace the Hard Disk Drive ⇒ Page 377. System Error: 07:10 Problem Description: Aerosol Fan driver burnt. Corrective Action: Try the following: • Replace the Interconnect PCA ⇒ Page 357. • If the System Error continues, replace the Sausalito PCI PCA ⇒ Page 369. NOTE:
Replace one part at a time and check if the error has cleared before replacing another. System Error: 08:11 Problem Description: Problem with communication between the Front Panel, the Formatter and the HDD. Corrective Action: Try the following: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the Front Panel cable is not damaged and is correctly connected to the Front Panel and to the Interconnect PCA. • Check that the Memory Module is installed correctly. • Check that the cables between the Interconnect PCA and the Main PCA are not damaged and are correctly connected.
• Check that the cables between the Hard Disk Drive and the Power Supply Unit and the Main PCA are not damaged and are correctly connected. • Check that the cable between the Power Supply Unit and the Main PCA is not damaged and is correctly connected. 50 Chapter 2 System Error Codes