MICR Control Commands (only for printers with MICR) DLE EOT BS n [Name] Real-time MICR status transmission [Format] ASCII DLE EOT BS n Hex 10 04 08 n Decimal 16 4 8 n [Range] n = 1 [Description] Transmits the selected MICR status specified by n in real time as follows: FS a 0 n [Name] Read check paper [Format] ASCII FS a 0 Hex 1C 61 30 Decimal 28 97 48 [Range] 0 ≤ n ≤ 255 [Description] Selects MICR function and reads MICR characters specified by n as follows: Readable Fonts 5-28 Commands n Function 1 Transmit MICR status Bit Off/On Hex Decimal Function 0 Readable fonts. See the table below. 1 2,3 - - - Undefined 4 Off 00 0 Not used. Fixed to Off. 5,6 - - - Undefined 7 Off 00 0 Not used.
Fixed to Off. Bit 1 Bit 0 Font 0 0 E13B 0 1 CMC7 1 0 Undefined 1 1 Undefined