Burst EN 10.7 Gate Polarity Gate polarity is only available in gated burst mode. The generator will output burst when the gated signal from the [FSK/Trig/Sync/Extmod] connector on the rear panel is "High Level" or "Low Level". When Burst is enabled, press Type softkey to select " Gate " and press Polarity softkey to select "Positive" or "Negative". The default is "Positive". 10.8 Trigger Output Edge In burst mode, when the trigger source is "Internal" or "Manual", the generator would output a TTL-compatible signal with specified edge from the [FSK/Trig/Sync/Extmod] connector on the rear panel. ⚫ Internal trigger:
The generator outputs a square waveform with variable duty cycle (related to the carrier period and number of cycles) from the [FSK/Trig/Sync/Extmod] connector at the start of the burst. ⚫ Manual trigger: The generator outputs a pulse from the [FSK/Trig/Sync/Extmod] ⚫ External Trigger: The [FSK/Trig/Sync/Extmod] connector is used as the input connector at the start of the burst. terminal of external trigger signal and has no trigger output. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD 66