Hantek — 3.14.3 SOURce<n>:HARMonic:ORDEr

Command system EN Return format None Example SOURce1: HARMonic: AMPL 1, 1 /* Set the amplitude of the 1st subharmonic of channel 1 to 1Vpp */ 3.14.2 SOURce :HARMonic:PHASe Command format SOURce :HARMonic:PHASe , |MINimum|MAXimum SOURce :HARMonic:PHASe? [,MINimum|MAXimum] Function description Set the phase of a specified subharmonic. Argument Instructions None Return format Return the phase value of the specified subharmonic as a scientific count. Example SOURce1: HARMonic: PHASe 1, living /* Set the phase of the 1st subharmonic of channel 1 to 90 degrees */ 3.14.3 SOURce :HARMonic:ORDEr Command format SOURce :HARMonic:ORDEr |MINimum|MAXimum SOURce :HARMonic:ORDEr?

[MINimum|MAXimum] Function description Set the number of harmonics. HDG300C Programming manual Copyright © Qingdao Hantek Electronics Co., LTD 42 Name Range Default value integer 1 to 16 1 continuous 0 to 360 degrees 0 real type