Hantek — 3.19.3 SOURce<n>:MOD:PM:INTernal:FUNCtion

Command system EN Return the phase deviation as a scientific count +9.000000000000000E+01. Example SOURce1:MOD:PM:DEViation 90 /* Set the phase of channel 1 to 90 degrees */ 3.19.2 SOURce :MOD:PM:INTernal:FREQuency Command format SOURce :MOD:PM:INTernal:FREQuency |MINimum|MAXimum SOURce :MOD:PM:INTernal:FREQuency? [MINimum|MAXimum] Function description Set the frequency of the modulated waveform. The waveform selected as the modulation source will operate at that frequency (within that waveform frequency limit). Argument Instructions This command can only be used with internal modulation sources (PM:SOURce INTernal). Return format Return the frequency value as a scientific count.

Example SOURce1:MOD:PM:INTernal:FREQuency 1000 /* Set the modulated wave frequency of channel 1 to 1000Hz */ 3.19.3 SOURce :MOD:PM:INTernal:FUNCtion Command format SOURce :MOD:PM:INTernal:FUNCtion SINusoid|SQUare|RAMP SOURce :MOD:PM:INTernal:FUNCtion? Function description Select the modulated waveform shape. Argument Copyright © Qingdao Hantek Electronics Co., LTD HDG300C Programming manual 49 Name Range Default value 2 mHz to 500 kHz 100Hz