Hantek — List Entry Stepping Rules:LIST:PACE

LIST:CURRent 0.5,0.6,(@1) /* Set channel 1 list entry current */ LIST:CURRent? (@1) /*Return 0.5,0.6*/ List Entry Voltage Value : LIST:VOLTage Command format LIST:VOLTage LIST:VOLTage? Function description Set or query the voltage value of the channel list entry. Parameter volt?: Voltage value, unit V, floating point. chn: Refer to the CURRent command. Description The number of voltages set must be equal to the number of list entries and correspond to the list entries one-to-one. Return value The query returns the voltage value of each list item of the query channel, unit V. For example LIST:VOLTage 5.5,6.6,(@1) /* Set the channel 1 list entry voltage */ LIST:VOLTage?

(@1) /*Return 5.5,6.6*/ List Item Duration : LIST:DWELl Command format LIST:DWELl LIST:DWELl? Function description Set or query the duration of channel list entries. Parameter time?: Time value, unit s, floating point. chn: Refer to the CURRent command. Description The number of set times must be equal to the number of list entries. Return value The query returns the duration of each list item of the query channel, unit s. For example LIST:DWELl 3.5,3.5,(@1) /* Set the duration of channel 1 list entry */ LIST:DWELl? (@1) /*Return 3.5,3.5*/ List Entry Stepping Rules : LIST:PACE Command format LIST:PACE 13