6 Configuring with the programming assistant rESEt E2 Error 2: Drive was removed during the configuration pro cess The USB drive was removed during configuration. The process is aborted. The counter must be restarted to reset any possible errors in the configuration. This is shown by the message “rE SEt” on the display. Press any key on the counter to restart it. In order to reconfigure the counter, remove the USB drive and insert again. rESEt E3 XXX Error 3: A configuration command has produced an error message A command error has occurred during configuration of the counter, i.e., one of the commands in the configuration file re ported an error.
The digits shown here as XXX (e.g., 014) refer to the command error in the configuration file. It represents the sequential number of the executed commands, not the row number. Example: If error “14” is displayed, the error is con tained in the 14th command in the configuration file, irrespec tive of how many comments are noted. USB Abort Configuration has been aborted This message appears in the display if the configuration pro cess is not started within the specified time after finding the configuration file, or if the process is manually aborted. The display returns to standard view after a couple of seconds. 18