HP — Building a Part

a. Do not press the Wait for Part button b. From your HP Designjet 3D Software Solution work station, send a part to the printer. c. The printer panel displays the name of the first model in the printer queue and Start Model is blinking. d. From the printer, press the Start Model button to begin building the displayed part. ii. Remote ‘Start Model’: - You send a part to the printer from your HP Designjet 3D Software Solution work station. The part automatically begins to build. a. From the printer, press the Wait for Part button b. Wait for Part is displayed in the upper window. Press Cancel if you wish to exit the remote start mode. c.

From your HP Designjet 3D Software Solution work station, send a part to the printer. The printer will automatically start to build the model. 3. If a part has been sent to the printer for build (there is at least one part in the build queue), but is not building: A. The panel displays Ready to Build. B. The name of the first model in the build queue is displayed. C. Start Model is blinking. Press the Start Model button to begin building the displayed part. Regardless of the method used to start building a part, the printer will perform the same sequence of steps: 1. The printer drops (lowers) the substrate sensor. 2.

System “touches down” six times which measures the height of the sub- strate. 3. SBC converts the model file (CMB) into the motion commands that the controller will execute to build the model. 4. System completes substrate measurement. 5. Z stage moves to bottom of Z travel. 6. Head moves over the purge bucket and prepares to build purging the appropriate tip. 7. Once purge is complete, the printer will start to build the model. During model construction, the printer will display the percentage of material remaining on each spool. During building the keypad will allow you to pause the printer, or turn on the chamber lights.

The printer will stay in the Building State until the model is finished or the printer pauses. If the printer pauses, it will enter a Pending Pause state until the current road is finished. -5 Note: Make sure an empty modeling base is installed, then answer Yes to the prompt Is Model Base Installed?