Step 1: Collecting all the project data 1.1 Installation / ambient conditions The checklist queries these installation and ambient conditions on site, which need to be provided by the planner. The manufacturer considers this information and assembles the distribution board according to these requirements. The measures and recommendations given must be considered for the safe operation of the distribution board. 1. Installation / ambient conditions Installation Type of business: ___________________________ Indoor / ambient temperature (°C): _______________ Indoor: in locked electrical operating room in production area Available wall surface in mm: Width: __________ Height: __________ Depth:
__________ Outdoors: protected outdoors unprotected outdoors Assembly type: wall-mounted fl oor-standing Degree of protection: IP 44 IP 54 IP 55 IP 65 IP _______________ Type of business Take into account special requirements for use in commercial and industrial applications, such as strong mechanical and chemical stress on assembly material. Room / ambient temperature (°C) according to IEC 61439 / EN 61439 Temperature range: -5°C to +35° C, max. +40°C Humidity: 50% at 40°C, 100% at 25°C Measures: Specify power dissipation of the assembly for the rating of the ventilation / room size. Higher ambient temperatures must be considered in planning.
Installation indoors In locked electrical operating room: Only accessible by skilled persons (electricians) During operation: Accessibility by unskilled persons IP degree of protection Protection against foreign bodies: dust-proof IP 6X Water protection: waterproof IP X6 / IP X5 (defl ected water without high pressure) Installation outdoors - Protected outdoors - Unprotected outdoors Direct sunlight The material has been tested for UV resistance. UV-resistant according to IEC 61439-1 / EN 61439-1 paragraph 10.2.4.
If necessary, protect with additional measures against direct sunlight, for example with canopy Temperature and humidity Higher ambient temperatures, possibly due to direct sunlight have to be considered in the planning stage. IP degree of protection for protected or unprotected outdoor installation Where appropriate, consider measures against occasional condensation forming as a result of temperature variations, such as venting, heating, air-conditioning (also with unprotected installation). Type of installation Specify the system type for wall-mounting or fl oor-standing installation Available sizes Consider installation conditions on site and specify restrictions as needed.
For details, see HENSEL main catalogue or www.hensel-electric.de. 10