● Scanner Model: ● Firmware Release: ● Firmware Build: ● Scanner ID: ● Mac Address: ● Serial Number: Test 6: Motor Test This test checks the functionality of the Stepper Motor and any associated electronics. When the test is executed, a menu appears that allows you to select the motor speed and the motor direction. If the Stepper Motor fails to run when the test is executed, then the Stepper Motor should be replaced. Test 9: Oscilloscope View This test contains a Software Oscilloscope that allows you to check the light profile of the CIS elements: ● Uncorrected light profile shows the raw data from the CIS module. ● Corrected light profile shows the calibrated data. Test 11:
Manual Camera Alignment Allows you to adjust either Vertical Alignment or Stitching between 2 CIS modules: 1. Load the calibration sheet. 2. Select Alignment or Stitching. 3. Select the two CIS modules to adjust (AB, BC, etc...). 4. Use the arrows to either increase or decrease the value until the preview of the transition area between both CIS modules look correctly aligned or stitched. 4 Chapter 1 Troubleshooting ENWW