HP — HP OmniBook 900 Service Manual (EN)

HP OmniBook 900 Troubleshooting and Diagnostics 3-15 Code Suggestions 0180h For 01FFFFFFh (OB900†) or 03FFFFFFh (OB900B) and below, replace the motherboard. Above that, replace the RAM board (each 01000000h represents 16MB). 0181h Replace the CPU module. 0182h Unload HIMEM.SYS or make sure that another application is not using all extended memory allocated by HIMEM.SYS. 0183h No extended memory. Check installation of any RAM board. Replace the motherboard. 0184h Remove or swap RAM boards. Replace the CPU module, replace the motherboard. 0190h - 01A0h For 01FFFFFFh (OB900†) or 03FFFFFFh (OB900B) and below, replace the motherboard.

Above that, replace the RAM board (each 01000000h represents 16MB). 01A1h - 01A4h Replace the CPU module. 01B1h – 01B3h For 01FFFFFFh (OB900†) or 03FFFFFFh (OB900B) and below, replace the motherboard. Above that, replace the RAM board (each 01000000h represents 16MB). Hard Disk Tests 0201h Replace the hard disk. Replace the motherboard. 0202h - 0204h Rerun the test. If error persists, replace the hard disk. 0205h Replace the motherboard. 0207h Run BIOS Setup and check the hard disk type. Check internal and external hard disk connectors and motherboard connector. Replace the hard disk. 0208h - 0209h Transient DMA error. Rerun the test. 020Ah - 0211h Rerun the test. Run SCANDISK or equivalent.

0220h Replace the motherboard. 0240h Replace the hard disk. Replace the motherboard. 0252h - 0254h Rerun the test. Run SCANDISK or equivalent. 025Ah - 0260h Rerun the test. If error persists, replace the hard disk. 0265h Check internal and external hard disk connectors and motherboard connector. Replace the hard disk. Replace the motherboard. 0275h Replace the hard disk. 0280h Check internal and external hard disk connectors and motherboard connector. Replace the hard disk. 0281h Replace the hard disk. 0290h Rerun the test. If the error persists, replace the hard disk. 0293h - 0296h Replace the hard disk. 02AAh Check internal and external hard disk connectors and motherboard connector.

Replace the hard disk. Code Suggestions 02CCh Run BIOS Setup and check the hard disk type. Replace the hard disk or the motherboard. 02EEh For the performance test, run BIOS Setup and temporarily select a drive type that has more than 200 cylinders. 02F1h Recreate the Hibernate partition, then run FDISK to partition the hard disk. 02F2h Run FDISK to make one partition active. If necessary, recreate the Hibernate partition, then run FDISK to partition the hard disk. 02F3h – 02F5h Run FDISK to check for overlapping partitions. If necessary, recreate the Hibernate partition, then run FDISK to partition the hard disk.

02F6h Recreate the Hibernate partition, then run FDISK to partition the hard disk. 02FFh Check internal and external hard disk connectors and motherboard connector. Replace the hard disk. Replace the motherboard. 9602h - 9607h (See Hard Disk Tests at the end of the table.) Floppy Disk Tests 0301h Replace the floppy drive. Replace the motherboard. 0302h Run BIOS Setup and check the floppy drive type. Replace the floppy drive. 0303h Insert a floppy disk without write protection. 0304h Run BIOS Setup and check the floppy drive type. Replace the floppy drive. 0305h Replace the motherboard. 0307h Run BIOS Setup and check the floppy drive type.

Check the connectors on the floppy drive, external module bay, and motherboard. Replace the floppy drive. 0308h - 0309h Transient DMA error. Rerun the test. 030Ah - 0310h Rerun the test with a good floppy disk. Replace the floppy drive. 0311h Rerun the test with another floppy disk. 0321h - 0322h Replace the floppy drive. 0340h Replace the motherboard. 0341h Replace the floppy drive. Replace the motherboard. 0342h - 0344h Run BIOS Setup and check the floppy drive type. Replace the floppy drive. 0345h Replace the motherboard. 0347h Run BIOS Setup and check the floppy drive type. Check the connectors on the floppy drive and motherboard. Replace the floppy drive.

0348h - 0349h Transient DMA error. Rerun the test. 0350h Rerun the test with another floppy disk. Replace the floppy drive. 0360h Replace the motherboard. 0380h - 03AAh Make sure the floppy disk is fully inserted. Check the connectors on the floppy drive, external module bay, and motherboard. Replace the floppy drive.