omron — Autotuning for Line-to-Line Resistance

EN-17 Param- eter Num- ber Name Description Initialize Data A1-00 Language selection for Digital Opera- tor dis- play(JVOP- 160-OY only) 0:English 2:German 3:French 4:Italian 5:Spanish 6:Portuguese A1-01 Parameter access level 0:Monitoring only (Monitoring drive mode and setting A1-01 and A1- 04.) 1:Used to select user parameters (Only parameters set in A2-01 to A2-32 can be read and set.) 2:Advanced (Parameters can be read and set in both, quick programming mode (Q) and advanced programming mode (A). A1-03 Initialize 0: No initializing 1110:Initializes using the user parameters 2220:Initializes using a two-wire sequence. (Initializes to the factory setting.) 3330:

Initializes using a three-wire sequence. Sequence / Reference Source b1-01 Reference source selec- tion Sets the frequency reference input method. 0:Digital Operator 1:Control circuit terminal (analog input) 2:Serial communication (RS422 / 485) 3:Option Card b1-02 RUN com- mand source selection Sets the run command input method.

0:Digital Operator 1:Control circuit terminal (digital inputs) 2:Serial communication (RS422 / 485) 3:Option Card b1-03 Stopping method selec- tion Selects the stopping method when the Run signal is removed 0:Deceleration to stop 1:Coast to stop 2:DC injection to stop 3:Coast to stop with timer (New Run commands are disregarded while coasting.) b1-04 Prohibition of reverse opera- tion 0:Reverse enabled 1:Reverse disabled 2:Output Phase Rotation (both rota- tional directions are enabled) 3:Output Phase Rotation with Reverse disabled.

Speed Search b3-01 Speed search selection (cur- rent detection or speed cal- culation) Enables/disables the speed search function and sets the speed search method. 0:Disabled, speed calculation 1:Enabled, speed calculation 2:Disabled, current detection 3:Enabled, current detection Param- eter Num- ber Name Description b3-14 Bi-directional speed search selection Disables or enables the bi-directional capabilities of the speed search func- tion. 0:Disabled 1:Enabled PI Control b5-01 PI control mode selec- tion 0:Disabled 1:Enabled 3:PI control enabled (frequency reference + PI output) b5-02 Proportional (P) gain Sets the proportional gain of the PI controller.

P control is not performed when set 0.00. b5-03 Integral (I) time Sets the integral time of the PI con- troller. I control is not performed when set to 0.0 sec. b5-09 PI output characteris- tics selection Selects forward/reverse direction for PI output. 0:PI output is forward 1:PI output is reverse. b5-17 Accel/decel time for PI ref- erence Sets the accel/decel time for the PI Softstarter (SFS). b5-18 PI Setpoint Selection 0:Disabled 1:Enabled b5-19 PI Setpoint PI target value Acceleration / Deceleration Settings C1- †† Acceleration/ Deceleration times Sets the time to accelerate/decelerate from 0 Hz to the maximum output fre- quency.

S-Curve Settings C2- †† S-curve char- acteristic time at acceleration Sets the S-curve characteristic at acceleration start and end. Carrier Frequency C6-02 Carrier fre- quency selec- tion Selects the carrier frequency (factory setting depends on Inverter capacity) 0: Low noise, low carrier 1: 2.0 kHz 2: 5.0 kHz 3: 8.0 kHz 4: 10.0 kHz 5: 12.5 kHz 6: 15.0 kHz F: Programmable pattern Speed Settings d1-01 to d1-04 Multi speed references 1 to 4 Sets the multi-step speed references. d1-17 Jog fre- quency refer- ence Reference Limits d2-01 Frequency ref- erence upper limit Sets the frequency reference upper limit in percent of the max.

output fre- quency (E1-04) d2-02 Frequency ref- erence lower limit Sets the frequency reference lower limit in percent of the max. output fre- quency (E1-04)