ibm PCjr — 3-019

Constant Value Head Load Not Applicable Head Settle 21 Milliseconds Motor Start 500 Milliseconds Drive Constants Comments 1. Head loads when diskette is clamped. 2. Following access, wait Head Settle time before RD/WR. 3. Drive motor should be I off I when not in use. Wait Motor Start time before RD/WR. 4. All system interrupts except IRQ6 must be I disabled I during diskette data transfer in order to prevent data under-run or over-run conditions from occurring. System 110 Channel Interface All signals are TTL-compatible:

Most-Positive Up-Level Least-Positive Up-Level Most-Positive Down-Level Least-Positive Down-Level + 5.5 Vdc + 2.7 Vdc + 0.5 Vdc - 0.5 Vdc The following lines are used by this adapter: +DOthru 7 (Bidirectional, Load: 174LS, Driver: 74LS 3-state) Diskette Drive Adapter 3-19