ibm PCjr — 2-027

control the bus, and must continue to assert the -HRQ until it is ready to relinquish the bus. A -HRQ is not an asynchronous signal and should be synchronized to the system clock. All channel devices with bus-master capabilities must latch data-bit 04 during any 'Out I instruction to AO-A7. The resulting signal should be used to qualify -HRQ as follows: Latched value = 1--> -HRQ is inhibited. Latched value =0 -- > -HRQ is allowed. For more detail, see the explanation of the AO port. DRQO o This line comes from the floppy disk controller (FOe) and can be used by an external DMA to indicate that a byte should be transferred to the FOC.

-DACKO I This line should come from an external OMA and should indicate that a byte is being transferred from memory to the FDC. HLDA o Hold Acknowledge: This line indicates to a bus master on the channel that -HRQ has been honored and that the 8088 has floated its bus and control lines. I/O Channel 2-27