Delta ISPSoft — 23.1.7 Control Mode - 2-axis linear interpolation motion

Chapter 23 Wizard Tool  Completion action: Go to next segment to complete the data and continue to the next. Completion refers to an end once data is complete.  Completion flag (I/M) : When the data execution is complete, set the register to ON. The register range is set as M0~M8191 or I510~I519 only when Completion action is set to Completion .  No. of next segment: Continue with the next data number, not limited to the same assigned axis number. But, take note that the same axis number cannot output more than 2 numbers from the table or output position command at the same time.

When Completion action is set to Completion , the number is automatically continued to the next segment Notice for table input: 1. The objective position cannot be set to 0 in the relative mode. The objective positions of two adjacent row numbers cannot be set to the same value in the absolute mode. 2. If the value in the ACC/DEC time is not 0, the acceleration/deceleration is fixed to 1ms. If the value in the ACC/DEC time is set to 0, it means there is no acceleration or deceleration. 3. I number can be used more than once. Users must determine through which row number the I number can be completely outputted. 4. The instruction which the start table outputs is API2718 TPO.

API2719 TPWS can be used to modify the output parameters while PLC is running. 23.1.7 Control Mode - 2-axis linear interpolation motion Description regarding 2-axis linear interpolation mode performs the motion on XY plane. Two data are used for this mode.  No. : The number is generated by the system, the 2-axis mode occupies two data. The second data No. will add a T in front of the number. Under 2-axis mode, the maximum No. is 100 and T100, a total of 100 set.  Control Mode: A motion type. Choose 2-axis linear interpolation motion .  Coord: The X or Y coordinates in the simulation graph.  Axis No.: An axis controlled by the data. 23-11