ISPSoft User Manual (4) If users want to modify the properties of a created POU, right-click Propertie s from the POU item and refer to pervious description for setup. The programming language cannot be changed when using edit on Properties. For DVPxxMC/ AS5xx series, editing Properties cannot change the task setting. DVPxxMC 5.4.2 POU Active State ISPSoft provides the function to temporarily close POUs. When POU is closed, the POU will be skipped for compiling and the internal process will also not be executed. However, this function only supports in program type POUs. This function is used for testing or debugging.
To skip some process beforehand, users can set POU as ineffective and restore to active testing is complete. The following example shows the equipment has five workstations and the task process is categorized into 5 POUs for development. Feeding Positioning Test A Test B Discharging 5-20