Delta ISPSoft — 2.4.3.6 Communication Parameter Setting - DVP Simulator

ISPSoft User Manual  Click Add for a new IP address and input information regarding each cell.  IP address: The device IP address.  Port: Used during communication, default setting is 502.  Label: The name of the device.  Type: The device model type that can be found through clicking Search .  Select an IP address and click Del or press Delete on the keyboard to remove it from the list. (5) To setup parameters concerning responding time. For Connect Retries, users need to setup the number of retry once connection error occurs, while for Connection Time-Out setting, the parameter concerns the time interval between retries. *.

When changing an internet device connected to a PC, users need to close the setting page concerning communication driver properties and re-start in order to obtain the new internet device. 2.4.3.6 Communication Parameter Setting - DVP Simulator (1) Type the Driver Name . To add special marks, only ‘_’ can be used. (2) For Connection Setup , select DVP Simulator from the drop-down list for Type . (3) Input assigned Port Number . (4) For Device Setting , DVP simulators include EH2/SV/Old Series, EH3/ EH3-L/SV2, ES2/ EX2/SA2/SX2/MC, SE and SS2 . (5) To setup parameters concerning responding time.

For Connect Retries, users need to setup the number of retry once connection error occurs, while for Connection Time-Out setting, the parameter concerns the time interval between retries. *. Regarding TP devices, please select SS2 series as simulator. *. When ES, SS, EX, VFD, EC devices download the DVP simulator, these devices will change to EH device once uploaded. 2-50