5.6 H: Terminal Functions Setting 2: Speed Agree (f ref /f out Agree ) Closes whenever the actual output frequency is within the current frequency reference regardless of the direction, plus or minus 2 Hz. Note: Detection works in both directions, forward and reverse. Frequency reference Output Speed agree Figure 5.22 Speed Agree Time Chart Refer to L4-01: Speed Agreement Detection Level on page 106 for details on setting the detection width. Setting 4: Frequency Detection 1 Output is closed as long as the output frequency is below the detection level set in L4-01 plus 2 Hz. It closes when the output frequency falls below L4-01. Note: The detection works in both forward and reverse.

The value of L4-01 will be used as the detection level for both directions. Output L4-01 Frequency detection 1 Figure 5.23 Frequency Detection 1 Time Chart Refer to L4-01: Speed Agreement Detection Level on page 106 for details on setting the detection width. Setting 5: Frequency Detection 2 Output closes whenever the output frequency is equal to or above the detection level set in L4-01. The output opens when the output frequency falls below L4-01 minus 2 Hz. Note: The detection works in both forward and reverse. The value of L4-01 will be used as the detection level for both directions.

96 SIEP C710606 33A OYMC AC Drive – J1000 User Manual Status Description Open Output frequency does not match the frequency reference while the drive is running. Closed Output frequency is within the range of frequency reference ± 2 Hz. y t 2 Hz ency OFF 2 Hz ON Status Description Open Output frequency exceeded L4-01 + 2 Hz. Closed Output frequency is below L4-01 or has not exceeded L4-01 + 2 Hz. quency 2 Hz L4-01 ON OFF 2 Hz Status Description Open Output frequency is below L4-01 minus 2 Hz or has not exceeded L4-01. Closed Output frequency exceeded L4-01.