Figure 6-263 Carrier Belt and Motor (2 of 2) CAUTION Do not disassemble the Carrier Motor Assembly. 3 Remove 2 TP screws (m3x6) from the bracket by the motor. 4 Lift the motor and unplug 1 connector from underneath the motor. Note The replacement Flatbed Motor Unit includes a replacement motor, a short belt, and a long belt. The cable, pulley shaft, and spring are ordered separately. To replace 1 Reverse the above procedure. 2 To adjust the tension of the Carrier Belt, tighten or loosen the screw shown in Figure 6-262. C4265-90907 Copy Module Flatbed Assemblies 571