The chart shows the dynamic range for this parameter: Dynamic range [default value] ETS-text Colour control type @ none @ Colour Temperature @ RGB @ RGBW @ xy-coordinate The chart shows the dynamic range for this parameter: Dynamic range [default value] Comment ETS-text Set the colour type of the group, you can set the colour scene of the group through the DCA app. Colour value on The detailed introduction of each colour control type will be introduced in the following chapters: Comment @ last colour value @ define colour value Uses this parameter to set the colour temperature of the connected ECGs/lamps in the group when DALI bus voltage falls down. @last colour value:
The colour temperature remains unchanged. @1000 K..10000 K [3000K] Use this parameter to seta desired colour temperature ECG Power On @ last colour value @ define colour value Uses this parameter to set the colour temperature of the connected ECGs/lamps in the group when AC power recovery. @last colour value: Use the colour temperature prior to the ECG being powered off. Colour Value @1000 K..10000 kK [3000K] DALI System Failure Colour Value * Colour control type- Colour Temperature Colour control type Colour value on DAL!
System Failure last colour value Colour value © define colour value © define colour value on 3000 Colour value on ECG Power On last colour value 3000 Colour value Switch-on Colour value Colour Temperature Keep last object value behavior Switch-on colour value ©) Use defined value 3000 © Colour temperature object format Use this parameter to seta desired colour temperature. 2-bytes Colour Temperature(DPT7.600) 1-byte Percentage(DPT5.001) Sending colour value status Note: The above parameters are only reset after downloading database, and will not be reset when KNX power is restored.
at change Colour changing fading time via dimming Switch-on Minimum colour temperature Maximum behavior colour temperature @ Keep last object value @ Use defined value Use colour function Central colour temperature(HCL) State after KNX power recovery When colour function is active. enable Reaction colour temperature on object “Colour Temperature” © Ignore Disable colour function object “Relative Colour Temperature” © Ignore Disable colour function object “Scene” © Ignore Disable colour function Enable HCL object on page Use this parameter to set the switch-on colour temperature of the connected ECGs/lamps in the group.
If you select "Keep last object value", the value is set to the “DALI A Configuration / A-HCL/Dim2Warm 101 prior to the lamp being switched off. functions 102