EPSON — Front section

L-6534VW Operation Guide Overview of the Product Press Parts Front section 22 Letter Name Explanation a Pilot lamp Indicates the status of the press. b Tape holder Set the tape used for splicing substrates. U “Tape Specifications” on page 68 c Ionizer adjustment panel Adjust the ion balance of the ionizer while viewing the display on the electric potential sensor to remove static electricity from the substrate. d Ink cartridge holders Install two ink cartridges for each color. e Unwinder side workbench Place to splice substrates when replacing a substrate or to check print results. f Corona treater Performs corona treatment for the substrate before printing.

This aims to process the surface of the substrate so that ink can be easily fixated. The blower runs during printing (dust removal function) to remove paper powder and dust on the substrate when corona treatment is not performed. U “Corona treater” on page 29 g Unwinder roll cover Open to load roll substrate. h Sub panel Turns the tension for the entire substrate feeder ON/OFF, and feeds the substrate. U “Control panel” on page 27 i Bottom front cover Open when the substrate is jammed or when performing maintenance.