EPSON — Inspection Frequency (High Capacity Usage)

L-6534VW Operation Guide Maintenance Inspection Frequency (High Capacity Usage) If the press is being operated at a high capacity, you should inspect the press more frequently. See the following table. As a guide to what constitutes high capacity usage, we have assumed three shifts in 24 hours represents continuous operation. If the inspection frequency states "Every shift," perform the inspection when changing shifts. The numbers in the following table refer to the figures in the references. 245 Location (References) No.

(Illustrati on) Inspection Points Inspection Frequency Corona treater U “Corona treater” on page 238 1 Corona rollers Every shift 2 Corona electrodes 3 Corona treating station Every other day Path channel U “Path channel” on page 239 4 Unwinder side workbench Every shift 5 Web cleaner 6 Unwinder side rollers 7 Paper width sensor 8 Eye mark sensor 9 Foreign substance detection roller 10 Drum 11 Curing unit 3 12 Rewinder side rollers 13 Ionizers Every other day 14 Paper edge sensor Every shift 15 Joint sensor 16 Roll diameter sensor Once a week