L-6534VW Operation Guide Overview of the Product 54 Item Explanation Uneven Color Adjustment Set when applying the uneven color adjustment value. Do Not Apply Does not apply the uneven color adjustment value. Standard Adjustment Value (default) Uses the predetermined adjustment value. This should normally be selected. Print Head Height Adjusts the height of the print head during printing. Normally, select 0 (standard). If the following problems occur during printing, change the Print Head Height setting.
❏ When foreign matter is frequently detected in the substrate feeding path ❏ When paper dust on the substrate adheres to the nozzles and causes streaks in the print outs ❏ When ink drips during printing and smudges the print surface If the print head is set too high, the print quality may decline. Set the appropriate print head height. a: Print head, b: Substrate Additional UV Lamp Curing Set to cure ink using the additional UV lamp curing unit. Do Not Apply The additional UV lamp curing unit is not used. Apply The additional UV lamp curing unit is used to cure ink.
If you are using film substrate, perform a test print to check that the substrate has not been damaged by the high temperature, and then select Apply. Additional UV Lamp Curing Unit Strength Set the strength of the UV emitted from the additional UV lamp curing unit within a range of 27 to 100%. Enabled when Additional UV Lamp Curing is set to Apply. Default value: 50 % However, if you select Film for Substrate Type in the Change Substrate screen and set Print Speed to 7.6 m/min (Reverse White), the UV light strength during operation is 27 to 50%.