SST: 09230-01010 09231-01010 09231-01020 NOTICE: Do not press the protruding areas around the ports A and bracket B. Do not use SST to press the areas indicated by the circle marks in the illustration. Use pliers and be careful not to damage the core plates. gn (b) Check the lock plate height H after completing the caulking. Plate height H: 8.8 m (0.346 in.) If the height is not within the specified height, readjust the stopper bolt of the handle and caulk the lock plate again. 3. INSTALL DRAIN PLUG (a) Install a new O-ring to the drain plug. (b) Install the drain plug. 4. INSPECT FOR WATER LEAKS (a) Plug the inlet and outlet pipes of the radiator with SST. SST:
09230-01010 (b) Using a radiator cap tester, apply pressure to the radiator. Test pressure: 177 kPa (1.8 kgf/cm 2 , 26 psi) (c) Submerge the radiator in water. (d) Inspect for leaks. HINT: On radiators with resin tanks, there is clearance between the tank and lock plate where a small amount of air will remain. This air is released when the radiator is submerged in water, giving the appearance of an air leak. Before performing the water leak test, first shake the radiator in the water until all air bubbles are released. 5. INSTALL SIDE SUPPORT cardia