Toyota — TERMINALS OF ECU

(d) Mount SST (C) in a vise. gn (e) Insert SST (B) into SST (C), and attach the pulley nut to SST (C). (f) To torque the pulley nut, turn SST (A) in the direction shown in the illustration. Torque: 111 N·m {1,125 kgf·cm, 81ft·lbf} (g) Remove the generator from SST (C). (h) Turn SST (B), and remove SST (A and B). 4. INSTALL GENERATOR BRUSH HOLDER ASSEMBLY (a) While pushing the 2 brushes toward the inside of the brush holder, insert a pin (φ1.0 mm (0.039 in.)) into the brush holder hole. (b) Install the generator brush holder with the 2 screws. Torque: 1.8 N·m {18 kgf·cm, 16in·lbf} (c) Pull out the pin from the generator brush holder. 5.

INSTALL GENERATOR REAR END COVER (a) Install the terminal insulator to the generator rectifier end frame. NOTICE: Pay attention the mounting orientation of the terminal insulator. cardia