Delta — Chapter 5 Specifications

Chapter 5 Specifications Laser Displacement Operating Manual 5-1 Chapter 5 Specifications Name Laser Displacement Sensing method Triangulation Model LD-040N LD-080N LD-150N Reference Distance 40mm 80mm 150mm Measurement Range ± 10mm ± 25mm ± 60mm Repeatability 2μm 5μm 15μm Interface Communication method: Digital I/O and RS485 Supports 9600, 19200, 38400, 115200, 460800 bps (Default value: 115200bps) Light Source Laser CLASS 2 Spot Size 50 x 15µm 90 x 25µm 168 x 40µm Input Voltage 12~24 VDC ± 10% Linearity ± 0.1% Response Time 1ms / 3ms / 5ms / 10ms (Default value:

1ms) Average 1 /2 /4 /8 /16 /32 /64 /128 /256 (Default value 64) Sampling Rate 1ms / 10ms / 100ms / 200ms / 300ms / 400ms / 500ms / 1000ms (Default value: 100ms) Indicator Laser ON: blue, Measurement range: green, Out of measurement range: orange, DO: yellow, DI:

red Protection Circuit Protection against reverse power connection, output overcurrent, power supply surge, output surge Operating Temperature 10°C ~ 50°C Storage Temperature -25ºC ~ 75ºC Ambient Humidity 30% ~ 85 % Enclosure Rating IP67 Ambient Light Resistance 5000lus or less Vibration Resistance 10 ~ 55 Hz, 1.5 mm, 3 axes for 2 hours Insulating Resistance 20MΩ or more Withstand Voltage 500 VAC 50 / 60 Hz 1min Certifications CE Materials Optical window: Glass; Case: Aluminium Cables M8 Connector (8 Pin) Dimensions 57mm × 42mm × 24mm