4. Motion Control Instructions Master scaling =1, slave scaling = 1, master offset = 0, slave offset = 40 360 Slave Position 220 100 60 100-60=40 Master Position 360 When master scaling = 1, slave scaling = 1, master offset = 0, slave offset = 40, slave position is that in the original cam curve plus 40° Master scaling =1, slave scaling = 1, master offset = 200, slave offset = 0 360 Slave Position 200 180 60 360 Master Position When master scaling = 1, slave scaling = 1, master offset = 200, slave offset = 0, slave position shifts 200 corresponding to the master position.
When master position is 0, slave position is the 180 corresponding to the master position 200 in the original cam curve. 4-74 DVP-MC operating manual