4. Motion Control Instruction 10% 50% 90% % M10 M11 M21 M15 M25 M18 M28 Axis 1 and axis 2 establish the e-cam relationship when M1 changes from OFF to ON. DMC_CamSwitch starts to be executed when M10 changes from OFF to ON. Output 1 has been high for one scan cycle when the e-cam operation reaches or exceeds Percent 1 value, that is, the master position of the cam curve is greater or equal to 2,000. M11 (Output 1) will be ON for one scan cycle and then change into OFF. M21 is set to ON as Output1 is ON. Output 5 has been high for one scan cycle when the e-cam operation reaches or exceeds Percent 5 value, that is, the master position of the cam curve is greater or equal to 10,000.
M15 (Output 5) will be ON for one scan cycle and then change into OFF. M25 is set to ON as Output 5 is ON. Output 8 has been high for one scan cycle when the e-cam operation reaches or exceeds Percent 8 value, that is, the master position of the cam curve is greater or equal to 18,000. M18 (Output 8) will be ON for one scan cycle and then change into OFF. M28 is set to ON as Output 8 is ON. 4-106 DVP-MC operating manual