Delta — 4.6.36. MOV_BW

4. Motion Control Instructions 4.6.36. MOV_BW Explanation of the instruction: MOV_BW is used for sending multiple bit device values to the word devices. When EN is on, the bit device data with S1 as the starting bit device data is sent to the register zone with D as the starting register and the bit device length is specified by S2. When the data length S2 is larger than maximum 64, it is counted as 64. And the part above 64 is invalid. Explanation of input and output parameter of the instruction: Note: If the bit device of the instruction exceeds the range of that of the controller, only the data in the bit device within the valid range can be sent.

DVP-MC operating manual 4-139 API Move multiple bit device values to multiple registers Controller MOV BW 163 _ 10MC11T Parameter Data Available Explanation name type device EN “MOV BW” is executed as “EN” turns on. _ BOOL M,I,Q, constant S1 The source where the data comes from. BOOL M,I,Q S2 The length of the bit device of the transmitted zone, the max value for S2 is 64. UINT Constant,D D The starting register of the target zone INT D