Siemens — LV1_2010_EN_........pdf Siemens (EN)

© Siemens AG 2010 BETA Low-Voltage Circuit Protection Introduction Overview 19 19/2 Siemens LV 1 · 2010 Miniature circuit breakers 5SP4, 5SP5, 5SY4, 5SY5, 5SY6, 5SY7, 5SY8 Miniature circuit breakers Miniature circuit breakers with plug-in terminal Miniature circuit breakers 1 + N in 1 MW Miniature circuit breakers according to UL 489 and IEC Circuit breaker terminals 5SP4, 5SP5, 5SY4, 5SY5, 5SY6, 5SY7, 5SY8 5SJ6 . . .-.KS 5SY6 0 5SJ4 . . .-.HG 5SK9 Miniature circuit breakers Tripping characteristic A, B, C, D B, C B, C B, C, D -- Rated current A 0.3 ... 125 10 ... 20 2 ... 40 0.3 ... 63 0.5 ...

10 Rated switching capacity kA 6, 10, 15, 25 6 6 14/10 -- NEOZED fuse DIAZED fuse Cylindrical fuse Class CC fuse LV HRC fuse LV HRC signal LV HRC fuse systems systems systems system links detectors bases 5SE2, 5SG 5SA ... 5SD, 3NW6, 3NW7, 3NW1, 3NW2 3NA, 3ND 3NX 3NH 5SF, 5SH 3NW8 3NW3, 3NW7 NEOZED fuse systems DIAZED fuse systems Cylindrical fuse systems Class CC fuse system LV HRC fuse links LV HRC signal detectors LV HRC fuse bases 5SE2, 5SG 5SA ...

5SD, 5SF, 5SH 3NW6, 3NW7, 3NW8 3NW1, 3NW2 3NW3, 3NW7 3NA, 3ND 3NX 3NH Low-Voltage Fuse Systems Operational classes gG gG gG, aM Slow/quick/slow, current limiting gG, aM -- -- Rated voltage V AC V DC 400 250 500/690/750 500/600/750 400/500 600 150/300 400/500/690 250/440 690 600 690 250/440 Rated current range A 2 ... 100 2 ... 100 0.5 ... 100 0.6 ... 30 2 ... 1250 -- 160 ... 1250 Lightning arresters, type 1 Combination surge arresters, type 1 and type 2 Surge arresters, type 2 Surge arresters, type 3 5SD7 5SD7 5SD7 5SD7 Overvoltage protection devices Rated voltage V AC 230/400 230/400 230 ... 415 24 ... 400 Rated arrester voltage V AC 350 350 260 ... 350 24 ...

230 Discharge capacity kA 25/100 25/100 15/30; 20/40 1 ... 3 Multimeters Multicounters LAN couplers E-counters E-counters instabus KNX Current transformers Measuring selector switches 7KT1 30 7KT1 31, 7KT1 34, 7KT1 35 7KT1 39 7KT1 5 7KT1 1 7KT1 2 7KT9 0 Three-phase measuring devices Application Display of 23 electrical mea- sured values for switchgear assemblies, infeed or out- going feeders. Display of 35 elec- trical measured values and con- sumption values in switchgear assem- blies, infeed or outgoing feeders. Up-to-date consumption data of the multimeter available worldwide over LAN data com- munication.

Measurement of consumption data and plant capacity utilization in three-phase systems of system components, offices or holiday apartments. Straight-through transformers for installation in distribution boards and non-contact measuring of primary currents. For switching over the phases for voltmeters and ammeters