Danfoss — mg20b602.pm6 (EN)

VLT ® 2000 Series Special conditions I EMC test results I Emission Subsequent test results have been obtained using a system with a VLT frequency converter (with RFI filter module) a screened control cable and control box with potentiometer, unscreened motor cable and mo- tor. Standard Port VLT 2000 type VLT 2000 type VLT 2000 type 2010-2030 208-240 V 2040-2050 208-240 V 2020-2060 380-460 V EN 55011 Line yes 1 no 2, 3 yes 1, 4 gr.1 Class A 150 KHz - 30 MHz EN 55011 Enclosure yes 1 no 2, 3 yes 1, 4 gr.1 Class A 30 MHz - 1 GHz 1 Using RFI and motor filter for unscreened motor cable. Max.100 m, see page 88.

2 RFI and motor filter not available for VLT 2040-2050, 3 x 208-240 V 3 VLT 2040-2050, 3 x 208-240 V are not available with built-in RFI filter. 4 VLT 2000 up to 415 V versions are available with built-in RFI filter. With the purpose of minimising the cable-conducted interference to the mains supply and the radiated interference from the frequency converter system, the motor cables should be kept as short as possible. According to experience, most installations represent only a slight risk of any interference from radiation. 90 MG.20.B6.02 – VLT is a registered Danfoss trademark