Siemens — Технические данные модуля EM 277 PROFIBUS-DP

Программируемый контроллер S7-200. Системное руководство ;================================================ ; GSD File для EM 277 PROFIBUS-DP с DPC31 ; MLFB : 6ES7 277-0AA2.-0XA0 ; DATE : 26-March-2001 ;================================================ #Profibus_DP ;General parameters [Общие параметры] GSD_Revision = 1 [Версия GSD] Vendor_Name = »Siemens» [Имя поставщика] Model_Name = »EM 277 PROFIBUS-DP» [Имя модели] Revision = »V1.02» [Версия] Ident_Number = 0x089D Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = »1.00» [Версия аппаратуры] Software_Release = »1.02» [Версия программ.

обеспечения] 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 2 ; Slave-Specification [Данные slave-устройства]:

OrderNumber=»6ES7 277-0AA2.-0XA0» [Номер для заказа] Periphery=»SIMATIC S5» [Периферия] Slave_Family=10@TdF@SIMATIC [Семейство slave- устройств] Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Set_Slave_Add_Supp = 0 Auto_Baud_supp = 1 Min_Slave_Intervall = 1 Fail_Safe = 0 Max_Diag_Data_Len = 6 Modul_Offset = 0 Modular_Station = 1 Max_Module = 1 Max_Input_len = 128 Max_Output_len = 128 Max_Data_len = 256 ; UserPrmData-Definition ExtUserPrmData=1 »I/O Offset in the V-memory» Unsigned16 0 0-10239 EndExtUserPrmData ; UserPrmData: Length and Preset:

User_Prm_Data_Len=3 User_Prm_Data= 0,0,0 Max_User_Prm_Data_Len=3 Ext_User_Prm_Data_Const(0)=0x00,0x00,0x00 Ext User Prm Data Ref(1)=1 ;================================================ ; Продолжение GSD-файла ;================================================ ; Module Definition List [Список определений модуля] Module = »2 Bytes Out/ 2 Bytes In -» 0x31 EndModule Module = »8 Bytes Out/ 8 Bytes In -» 0x37 EndModule Module = »32 Bytes Out/ 32 Bytes In -» 0xC0,0x1F,0x1F EndModule Module = »64 Bytes Out/ 64 Bytes In -» 0xC0,0x3F,0x3F EndModule Module = »1 Word Out/ 1 Word In -» 0x70 EndModule Module = »2 Word Out/ 2 Word In -» 0x71 EndModule Module = »4 Word Out/ 4 Word In -» 0x73 EndModule Module = »8 Word Out/ 8 Word In -» 0x77 EndModule Module = »16 Word Out/ 16 Word In -» 0x7F EndModule Module = »32 Word Out/ 32 Word In -» 0xC0,0x5F,0x5F EndModule Module = »2 Word Out/ 8 Word In -» 0xC0,0x41,0x47 EndModule Module = »4 Word Out/ 16 Word In -» 0xC0,0x43,0x4F EndModule Module = »8 Word Out/ 32 Word In -» 0xC0,0x47,0x5F EndModule Module = »8 Word Out/ 2 Word In -» 0xC0,0x47,0x41 EndModule Module = »16 Word Out/ 4 Word In -» 0xC0,0x4F,0x43 EndModule Module = »32 Word Out/ 8 Word In -» 0xC0,0x5F,0x47 EndModule Module = »4 Byte buffer I/O -» 0xB3 EndModule Module = »8 Byte buffer I/O -» 0xB7 EndModule Module = »12 Byte buffer I/O -» 0xBB EndModule Module = »16 Byte buffer I/O -» 0xBF EndModule Рис.

A–28. Распечатка GSD-файла для модуля EM 277 PROFIBUS 434