Siemens · 2 стр.

Datasheet: Schenck Process VME 28061 Inclination Correction System (EN)

Оригинальное название: BVD2375GB 0951-rot

Читать онлайн

Похожие инструкции

Текст документа

Correction system for Scales with variable Weigher Inclination % Suited for any scales such as belt weighers or platform scales % Angle range: +/- 0° to +/- 16° % Robust structure, IP 65 Application The inclination correction system VME 28061 is used for correcting the measuring signal of a weighing unit if the inclination is variable. It is preferred for use with belt weighers. Function An inclined scale only meas- ures a weight of the mass to be measured that is reduced by the cosine of the angle. The VME 28061 corrects this fault on the electrical output of a strain gauge load cell.

The correct functions are not depending upon the load cell model and number nor the design of the electronic measuring unit as long as the electronic supplies the load cell with max. 12 V. Structure The device measures the inclination electronically and in accordance with the incli- nation corrects the signal of the load cell. It is installed in an IP 65 enclosure. The de- vice is mounted at a location with the same inclination as the scale to be corrected. The system is roughly aligned at the scale. Fine tuning is done electronically. BV-D2375GB

Стр. 1

Uncorrected readings of inclined scales Example of how to connect VME 28061 Technical Specifications BV-D2375GB 0951 All information is given without obligation. All specifications are subject to change. © by Schenck Process GmbH, 2009 Dimension Schenck Process GmbH Pallaswiesenstr. 100 64293 Darmstadt, Germany T +49 6151 1531-1216 F +49 6151 1531-1172 sales@schenckprocess.com www.schenckprocess.com Inclination Reading error 2,5° -0,1% 5,0° -0,4% 10,0° -1,5% 15,0° -3,4% 20,0° -6,0% Inclination range -16° ... + 16° to the horizontal Residual correction error in the operating temperature range Power supply 18 ...

36 VDC (isolation is realised in the VME 28061) Load cell supply voltage 12 Vpp AC or DC max. Operating temperature range -25°C ... +60°C Avoid direct sunlight Storage temperature range -40°C ... +80°C Signal wire cable cross- section Max. 1.5 mm2 Supply voltage cable cross- section Max. 2.5 mm2 Protection class IP 65 Dimensions W x H x D (cable inlets not considered) 122 x 120 x 90 mm Weight 1500 g Approbation CE 1 Load cell 2 Tachometer 1 3 Tachometer 2 4 Control electronics