Delta — Load Cell Module DVP02LC-SL — Operation Manual by Delta Electronics (EN)

Load Cell Module DVP02LC-SL Example: If you use a load cell of eigenvalue 3.8 mV/V, please set CR#2 to “2” to acquire the best ENOB. When CR#3 is set to “2 ms”, the ENOB will be 19 bits. When CR#3 is set to “20 ms”, the ENOB will be 20.5 bits. * For explanations on CR#2 and CR#3, see 5.2. 3 Product Profile and Outline 3.1 Dimensions DVP02LC ERROR POWER R UN EXC+ EXC- SIG+ L.V CH1 SEN+ SIG- ZERO NET SEN- SHD 3.2 Product Profiles DVP02LC ERROR POW ER RUN EXC+ EXC- L.V CH1 SEN+ SIG- SIG+ ZERO N ET SEN- SHD MAX MOTION EXC+ EXC- NET C H2 SEN+ SIG+ SIG- MOTION MAX ZERO SHD SEN- 1. Mounting hole for the I/O module 2. DIN rail slot (35mm) 3. I/O module connection port 4. I/O module clip 5.

Status indicators (POWER, RUN, ERROR, L.V) 6. Function status indicators (NET, ZERO, MAX, MOTION) 7. I/O terminals 8. RS-232 port 9. DIN rail clip 10. RS-485 port 11. DC power input DVP-PLC Operation Manual 5 mm 90 3 mm MAX MOTION EXC+ EXC- SIG+ CH2 SIG- N ET SEN+ ZERO SEN- MAX SHD MOTION 60 mm 33 mm